skip to content
 
Suzaku Guest Observer Facility

HXD Responses and Backgrounds for Simulations: Cycle 5 Versions

2009 September, HXD Team


1: Introduction

The HXD covers the highest energy range of the Suzaku band-pass, from 10 to 600 keV. The detector is a collimated well-type phoswich array designed to achieve the lowest background, and therefore the highest sensitivity ever achieved, in this band.

In spite of the low detector background, the sensitivity of the HXD is dominated by the systematic error of the instrumental background estimates. We suggest you fully take into account this error in all simulations.

To restate: only objects brighter than the systematic error of the background estimate at the energy band in question are detectable.

The background systematic error will have an energy dependence as well as a time dependence. See Technical Description for details. For example, with 100 ks exposure, the systematic erors are +/-3% for PIN in the 15-40 keV band and 1.5% for GSO in the 50-100 keV band.

2: Responses and Background Files

Files can be obtained individually following the links below, or collectively by downloading this gzipped tar file containing all 6 (note, however, that the response files are identical to those found in the Suzaku CALDB).

For the PIN

For the GSO

Notes

  • The background files are generated based on the Lockman hole observation performed on 2009-06-12. The PIN threshold (and hence the response) of epoch-5 is applied. The PIN background includes CXB contribution, and simulated to have an exposure of 3 Ms. In the GSO case, CXB is negligible and is also simulated to have an exposure of 3 Ms.
  • Please note that we do not have separate rmf and arf files for the HXD for observations at the standard pointing positions.
  • The effective area of PIN is roughly 10% higher when a point source is observed at the "HXD nominal" pointing position, compared with the default ("XIS nominal") position. The GSO response files have identical effective areas at these pointing positions, although the off-diagonal elements are slightly different.
  • Please also note that the background in the above files drops sharply above ~77 keV for the PIN, and ~750 keV for the GSO. These are outside the nominal bandpass of these detectors, and should not affect the feasibility studies.

3: Simulation procedure of HXD data for Cycle 5

For an accurate feasibility study, systematic uncertainties in the background estimation must be taken into account. This can be done by reading the background files into xspec both as background and correction files, and then using the cornorm command. See Chapter 4 of Technical Description for details.


If you have any questions concerning Suzaku, visit the Feedback form.

This file was last modified on Thursday, 15-Oct-2009 11:57:33 EDT